Load cell datasheets lead with accuracy figures. The number that decides whether a scale is usable in production is often a smaller one further down: the return to zero, or hysteresis, expressed as a percentage of full scale.
What hysteresis is
Load a cell to capacity, then remove the load, and the reading should return to zero. In practice it returns to a small non-zero value. That residual, measured after a defined settling time, is hysteresis.
On a single weighing the residual is negligible. On a batch scale where the operator tars between every item, the residual is accumulated into the tare, and the drift becomes systematic.
| Value | Typical spec | On a 1000 kg scale |
|---|---|---|
| non-linearity | 0.02 % FS | 200 g |
| hysteresis | 0.02 % FS | 200 g |
| creep (30 min) | 0.02 % FS | 200 g |
Why it accumulates
Consider a scale that weighs items one at a time with a tare before each. Each cycle leaves a residual of 0.02 % of full scale. If the tare is taken before the load is fully removed, or before the cell has settled, the residual is built into the next zero.
Over a shift of several hundred cycles the error does not average out — it drifts in one direction, because the residual after loading is always in the same sense. The operator notices that the scale "reads light" by the end of the shift and re-zeros it, without identifying why.
Settling time is the hidden variable
Hysteresis is specified after a defined settling period, commonly 30 seconds. A reading taken two seconds after unloading includes elastic recovery that has not finished, and the residual looks larger than the specification.
The practical consequence: a scale that tares immediately after removing a load accumulates more error than one that waits. On a fast production line nobody waits, so the specification's 30 seconds is never achieved and the real error exceeds the datasheet value.
What causes high hysteresis
Three sources:
The strain gauge bond. Adhesive that is slightly too thick, or cured at the wrong temperature, allows relative movement between foil and substrate. The gauge does not return to its original position.
Mechanical friction in the load path. Any joint that carries load and can slip — a pin in a hole, a bolted connection with clearance — introduces hysteretic behaviour that is not the cell's fault but appears in the reading.
Overload history. A cell that has been overloaded once has residual stresses that show as increased hysteresis permanently.
How to measure it
Load to capacity, hold for a defined time, unload, and record the reading at 30 seconds, 1 minute and 5 minutes. The curve of return tells you whether the residual is elastic (settles) or permanent (does not).
Repeat three times. A cell whose residual is consistent is behaving to specification; one whose residual grows with each cycle has a mechanical problem in the load path.
What to specify
For a scale used with frequent taring, hysteresis matters more than non-linearity, because it is the error that accumulates. A cell with 0.01 % hysteresis and 0.03 % non-linearity is a better choice for batch weighing than the reverse, even though the headline accuracy figure looks worse.
The datasheet does not make that trade-off for you. It lists both numbers, and the application decides which one matters.